Sign In | Join Free | My himfr.com
Home > MTL Instruments >

MTL5575 MTL Industries Temperature Converter

    Buy cheap MTL5575 MTL Industries Temperature Converter from wholesalers
     
    Buy cheap MTL5575 MTL Industries Temperature Converter from wholesalers
    • Buy cheap MTL5575 MTL Industries Temperature Converter from wholesalers
    • Buy cheap MTL5575 MTL Industries Temperature Converter from wholesalers

    MTL5575 MTL Industries Temperature Converter

    Ask Lasest Price
    Brand Name : MTL
    Model Number : MTL5575
    Certification : HART
    Price : Negotiable
    Payment Terms : T/T, Alipay, Paypal
    Supply Ability : 1000pcs per week
    Delivery Time : Negotiable
    • Product Details
    • Company Profile

    MTL5575 MTL Industries Temperature Converter

    MTL5575 MTL Instruments Temperature Converter


    The MTL5575 converts a low-level dc signal from a temperature sensor mounted in a hazardous area into a 4/20mA current for driving a safe-area load. Software selectable features include linearisation, ranging, monitoring, testing and tagging for all thermocouple types and 2-, 3-or 4-wire RTDs. (For thermocouple applications the HAZ-CJC plug on terminals 1–3 includes an integral CJC sensor). Configuration is carried out using a personal computer. A single alarm output is provided and may be configured for process alarm or to provide notice of early thermocouple failure.


    SPECIFICATION
    See also common specification

    • Number of channels
    One
    • Signal source
    THC types J, K, T, E, R, S, B or N to BS 60584 and XK mV input
    RTDs 2/3/4-wire platinum to BS 60751
    Pt 100, Pt 500, Pt 1000
    Cu-50 & Cu-53
    Ni 100/500/1000 DIN 43760
    • Location of signal source
    Zone 0, IIC, T4-6 hazardous area
    Division 1, Group A, hazardous location
    • Input signal range
    –75 to +75mV, or 0 to 400Ω (0 to 1000Ω Pt & Ni sensors)
    • Input signal span
    3 to 150mV, or 10 to 400Ω (10 to 1000Ω Pt & Ni sensors)
    • RTD excitation current
    200µA nominal
    • Cold junction compensation
    Automatic or selectable
    • Cold junction compensation error
    ≤ 1.0°C
    • Common mode rejection
    120dB for 240V at 50Hz or 60Hz (500ms response)
    • Series mode rejection
    40dB for 50Hz or 60Hz
    • .Calibration accuracy (at 20°C)
    (includes hysteresis, non-linearity and repeatability)
    Inputs: (500ms response)
    mV/THC: ± 15µV or ± 0.05% of input value(whichever is greater)
    RTD: ± 80mΩ
    Output: ± 11µA
    • Temperature drift (typical)
    Inputs:
    mV/THC: ± 0.003% of input value/°C
    RTD: ± 7mΩ/°C
    Output: ± 0.6µA/°C
    • Example of calibration accuracy and temperature drift
    (RTD input - 500ms response)
    Span: 250Ω
    Accuracy: ± (0.08/250 + 11/16000) x 100%
    = 0.1% of span
    Temperature drift: ± (0.007/250 x 16000 + 0.6) µA/°C
    = ±1.0µA/°C
    • Safety drive on sensor failure
    Upscale, downscale, or off
    • Early burnout
    Early burnout detection for thermocouples (when selected)
    Alarm trips when loop resistance increase is > 50Ω
    • Output range
    4 to 20mA nominal into 600Ω max.
    • Alarm output (configurable)
    Relay ON in alarm, 250mA @ 35V max
    • Maximum lead resistance (THC)
    600Ω
    • Response time
    Configurable - 500 ms default(Accuracy at 100/200ms - contact MTL)
    • LED indicator
    Green: power and status indication
    Yellow: alarm indication, on when contacts are closed
    • Maximum current consumption (with 20mA signal)
    50mA at 24V
    • Power dissipation within unit (with 20mA signal)
    1.2W at 24V
    • Safety description
    Refer to certificate for parameters. Um=253V rms or dc
    • Configurator
    A personal computer running MTL PCS45 software with a
    PCL45USB serial interface



    Related Models:

    HCU16MTL5521
    HCU3700MTL5522
    HM64RIB20-1.0MTL5531
    HM64RIB20-1.5MTL5532
    HMM64MTL5541
    HMRIB16-1.0MTL5541S
    HMS64MTL5544
    HTP-SC32MTL5544D
    MTL4044DMTL5546
    MTL4511MTL5546Y
    MTL4516MTL5561
    MTL4516CMTL5573
    MTL4521MTL5575
    MTL4541MTL5582B
    MTL4541MTL7728+
    MTL4544MTL7756AC
    MTL4544DMTL7760AC
    MTL4546YMTL7761PAC
    MTL4549YMTL7765AC
    MTL4573MTL7787+
    MTL4575MTL7787P+
    MTL4646YMTLCPS16
    MTL4850NJ5-18GK-N
    MTL4851SD150X
    MTL4852SD32
    MTL5018SD32X
    MTL5032SDRTD
    MTL5042SLP32D
    MTL5044TP48-3-I-NDI
    MTL5049TP48-3-N-NDI
    MTL5511TP48-4-I-NDI
    MTL5514DTP48-4-N-NDI
    MTL5516TP48-N-NDI
    MTL5516CZB24571

    Company Introduction:
    Achievers Automation Limited has more than 10 years experience in the market of Industrial Automation, specialized in reselling factory sealed Probe, Sensor, DCS,isolator barrier, HMI, PLC,Adapter,Profibus connector and cable from Brands as BENTLY NEVADA, Endress+Hauser, YOKOGAWA,MTL,Allen-Bradley, Pepperl+Fuchs,Rosemount, ASCO, Schneider, Lenze, Pro-face, Mitsubishi, Omron, Lenze, Delta, Honeywell, Siemens and etc. If you have any request, please do not hesitate to contact us.

    FAQ of Achievers
    Q:Are the Products Genuine OEM Units?
    A: These items have been certified by Achievers Automation Limited to be genuine OEM Units obtained through OEM or independent third-party channels.
    Q:How will you arrange shipment?
    A: We can arrange shipment based on your request. We have cooperated forwader who can arrange shipment via FedEx, DHL,TNT with good price.
    Q:What is the warranty of goods?
    A: One-year Warranty.

    Quality MTL5575 MTL Industries Temperature Converter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Achievers Automation Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)