    KFA6-SR2-EX2.W PEPPERL FUCHS Isolated Barrier Switch Amplifier 2 Channel

    Ask Lasest Price
    Brand Name : PF
    Model Number : KFA6-SR2-EX2.W
    Certification : ATEX
    Price : Negotiate
    Payment Terms : T/T, Alipay, Paypal
    Supply Ability : 100pcs per month
    Delivery Time : stock
    • Product Details
    • Company Profile

    KFA6-SR2-EX2.W PEPPERL FUCHS Isolated Barrier Switch Amplifier 2 Channel

    Product Details:
    Manufacturer : Pepperl+Fuchs
    Product No. : KFA6-SR2-EX2.W
    Product Type : Switch Amplifier


    Features:

    • 2-channel isolated barrier
    • 230 V AC supply
    • Dry contact or NAMUR inputs
    • Relay contact output
    • Line fault detection (LFD)
    • Reversible mode of operation
    • Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN

    Function

    This isolated barrier is used for intrinsic safety applications. It transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to a safe area.

    The proximity sensor or switch controls a form C changeover relay contact for the safe area load. The normal output state can be reversed using switches S1 and S2. Switch S3 is used to enable or disable line fault detection of the field circuit.

    During an error condition, the relays revert to their de-energized state and the LEDs indicate the fault according to NAMUR NE44.


    Technical data

    1. General specifications
    Signal type: Digital Input
    2. Functional safety related parameters
    Safety Integrity Level (SIL): SIL 2
    3. Supply
    Connection: terminals 14, 15
    Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz
    Power dissipation: 1.2 W
    Power consumption: max. 1.3 W
    4. Input
    Connection side: field side
    Connection: terminals 1+, 2+, 3-; 4+, 5+, 6-
    Rated values: acc. to EN 60947-5-6 (NAMUR)
    Open circuit voltage/short-circuit current: approx. 8 V DC / approx. 8 mA
    Switching point/switching hysteresis: 1.2 ... 2.1 mA / approx. 0.2 mA
    Line fault detection: breakage I ≤ 0.1 mA , short-circuit I > 6 mA
    Pulse/Pause ratio: min. 20 ms / min. 20 ms
    5. Output
    Connection side: control side
    Connection: output I: terminals 7, 8, 9 ; output II: terminals 10, 11, 12
    Output I, II: signal ; relay
    Contact loading: 253 V AC/2 A/cos φ > 0.7; 126.5 V AC/4 A/cos φ > 0.7; 40 V DC/2 A resistive load
    Energized/De-energized delay: approx. 20 ms / approx. 20 ms
    Mechanical life: 107 switching cycles
    6. Transfer characteristics
    Switching frequency: ≤ 10 Hz
    7. Galvanic isolation
    Input/Output: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
    Input/power supply: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
    Output/power supply: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
    Output/Output: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
    8. Indicators/settings
    Display elements: LEDs
    Labeling: space for labeling at the front


    Related Models:

    KCD2-SCD-EX1NBB5-18GM50-E2-V1
    KCD2-STC-EX1.20NBB8-18GM60-A2-V1
    KFA6-DWB-EX1.DNBN3-F25F-E8-V1
    KFA6-SR2-Ex2.WNBN40-U1K-N0
    KFD0-CS-Ex1.50PNBN40-U4LK-N0
    KFD0-HMS-16NBVB15-U1.Z2
    KFD0-RSH-1.4S.PS2NCB5-18GM40-NO
    KFD0-SD2-EX1.10100NJ10-30GM-N-5M
    KFD0-SD2-EX1.1045NJ15-30GK-N
    KFD2-UT2-1NJ2-12GK-SN
    KFD2-CD-1.32NJ2-12GM-N
    KFD2-CD-EX1.32NJ4-12GK-SN
    KFD2-HMM-16NJ5-18GK-N
    KFD2-SH-EX1.TNJ5-18GK-N-150
    KFD2-SH-Ex1.T.OPNJ5-18GM-N
    KFD2-SL2-EX2.BNJ8-18GK-N
    KFD2-SR2-EX1.WRD0-FB-EX4
    KFD2-SR2-Ex2.WRD0-FB-EX4.COM
    KFD2-STC5-1.2OSC3,5-G-N0
    KFD2-STC5-Ex1SC3,5-G-N0-5M
    KFD2-STC5-Ex1.HSC3,5-G-N0-6M
    KFD2-UT2-1SJ3,5-N
    KFD2-VR4-EX1.26SJ3,5-S1N
    KFU8-UFC-1.DUPR-03
    KFU8-UFTV15-G-2M
    K-HM26-2M-261533Z 787
    NBB15-U1-E2Z787.H
    NBB15-U1-Z2HIC2031


    Company Introduction:
    Achievers Automation Limited has more than 10 years experience in the market of Industrial Automation, specialized in reselling factory sealed Probe, Sensor, DCS,isolator barrier, HMI, PLC,Adapter,Profibus connector and cable from Brands as BENTLY NEVADA, Endress+Hauser, YOKOGAWA,MTL,Allen-Bradley, Pepperl+Fuchs,Rosemount, ASCO, Schneider, Lenze, Pro-face, Mitsubishi, Omron, Lenze, Delta, Honeywell, Siemens and etc. If you have any request, please do not hesitate to contact us.

    FAQ of Achievers
    Q:Are the Products Genuine OEM Units?
    A: These items have been certified by Achievers Automation Limited to be genuine OEM Units obtained through OEM or independent third-party channels.
    Q:How will you arrange shipment?
    A: We can arrange shipment based on your request. We have cooperated forwader who can arrange shipment via FedEx, DHL,TNT with good price.
    Q:What is the warranty of goods?
    A: One-year Warranty.

    Quality KFA6-SR2-EX2.W PEPPERL FUCHS Isolated Barrier Switch Amplifier 2 Channel for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Achievers Automation Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)